Tina, Giuseppe Marco

N/A
Università degli Studi di Catania

About

None

Experience

No experience added yet.

Education

No education added yet.

Skills

No skills

Other Publications

Cooperative Strategy for Optimal Management of Smart Grids by Wavelet RNNs and Cloud Computing

IEEE TRANSACTIONS ON NEURAL NETWORKS AND LEARNING SYSTEMS, Oct 2015

Advanced smart grids have several power sources that contribute with their own irregular dynamic to the power production, while load nodes have another dynamic. Several factors have to be considered when using the owned power sources for satisfying the demand, i.e., production rate, battery charge and status, variable cost of externally bought energy, and so on. The objective of this paper is to develop appropriate neural network architectures that automatically and continuously govern power production and dispatch, in order to maximize the overall benefit over a long time. Such a control will improve the fundamental work of a smart grid. For this, status data of several components have to be gathered, and then an estimate of future power production and demand is needed. Hence, the neural network-driven forecasts are apt in this paper for renewable nonprogrammable energy sources. Then, the produced energy as well as the stored one can be supplied to consumers inside a smart grid, by means of digital technology. Among the sought benefits, reduced costs and increasing reliability and transparency are paramount.

Enhanced models for the evaluation of electrical efficiency of PV/T modules

Solar energy, Aug 2021

Recently increasing attention has been paid on photovoltaic/thermal (PV/T) solar systems as these systems allow to generate heat and electricity simultaneously. Thermal and electrical performance of PV/T modules are coupled, so it is crucial to monitor both efficiencies to decide the optimal operating point. In this context, this paper aims to investigate numerically and experimentally the electrical energy performance of PV/T modules suitable to be used for online monitoring and control purposes. This study proposes a novel methodology for the evaluation of the electrical efficiency of PV/T modules as a function of the temperature of the cooling fluid, the solar radiation and the solar incidence angle. The proposed methodology is based on the calculation of the cell temperature of the PV/T module, which is in turn a function of the temperature of the cooling fluid and the specific features of the PV/T module. Models proposed in the literature for the evaluation of the electrical efficiency for PV modules have been redrafted, adapting them to PV/T modules. The proposed methodology has been validated using the experimental data carried out on an unglazed pilot PV/T plant located in Catania (Italy). The comparison between the calculated data by the developed redrafted models and observed data gives rises to a normalized Root Mean Square Error (nRMSE) of 9.73%. It is worth noticing that the accuracy of the models increases taking into consideration of the dependence of the electrical efficiency from the solar incidence angle (nRMSE equal to 8.99%).

Multilayer thermal model for evaluating the performances of monofacial and bifacial photovoltaic modules

IEEE Journal of Photovoltaics, Apr 2020

This article aims to present a novel mono-dimensional multilayer mathematical model apt to estimate the temperature of photovoltaic (PV) cells for both monofacial and bifacial PV modules. A dynamic three-layer model (3L-NM) has been developed, in which the contribution of solar radiation that hits the back of the PV module is included. The model is constituted by energy balance equations, one for each layer of the PV module. The input data of the proposed model are the environmental weather conditions as well as the withdrawal electrical power. The outputs are the average temperature of each layer, so it is possible to determine the PV cell temperatures that typically cannot be directly measured. With the purpose to investigate the reliability of the proposed model, the numerical results have been compared with experimental data. Finally, a sensitivity analysis has been performed to evaluate the impact of solar radiation in the back of the PV module considering the different wind speed, as well as the operating electrical points (open circuit and maximum power point). From the statistical analysis, correlation values of 0.993 and 0.990 were obtained, PE values equal to 0.718% and 0.161%, respectively, for the monofacial and bifacial module. The sensitivity study shows that the solar radiation on the backside of the module has a greater impact on the bifacial module, infact, when the contribution of back is included in a model, temperature differences up to 5.2 °C for bifacial and 1.0 °C for monofacial module at 1000 W/m2 were observed.

Technical and economic analysis of the provision of ancillary services through the flexibility of HVAC system in shopping centers

Energy, Nov 2022

To address the increasing demand for ancillary services, new demand response strategies (DR) are being developed that involve the building sector to provide flexibility to the transmission system operator (TSO). In this respect, commercial buildings have great potential to become key players in providing flexibility to the TSO by changing their load profiles for heating, ventilation and air conditioning. This study presents a case study of a Mediterranean shopping centre heated and cooled by a heat pump and participating in the ancillary services market according to the specific rules of the Italian pilot project UVAM. The analyses start from the daily consumption profile assuming conventional operation for the HVAC system (baseline) during cooling and heating periods. Then two DR strategies are investigated, the first of which is to change the indoor set point temperature and the second is to reduce the electricity power to the HVAC systems, without introducing pre-cooling or pre-heating periods. The results show that the studied flexibility strategies allow to obtain, for each DR event, over 60 kW of downward flexibility power and a reduction of energy consumption between 128 and 160 kWh during summer, and over 50 kW of downward flexibility power and a reduction of energy consumption between 40 and 160 kWh. This study identifies opportunities and barriers for commercial buildings to participate in the ancillary services market. However, the proposed DR strategies may lead to an unacceptable percentage of dissatisfaction (PPD), especially during the cooling season.

Collaborator Notes

No notes yet.

Sign in to write a note.

Sign in to message, connect with or follow Tina, Giuseppe Marco.